There is no cost to test the network.
Band Plan
Customers should use
- LoRaWAN IN 865 MHz modules and devices. The 3 default frequencies are 865.0625, 865.4025, and 865.9850 MHz. For better performance and reliability, configure the remaining 5 channels below (864.8625, 865.6025, 866.2, 866.4, and 866.6 MHz) on the module or device, or
- LoRaWAN EU 868 MHz modules and devices. These need to be configured to operate at the frequencies below (channels 0-7) as we do not use the EU default frequencies of 868.1, 868.3, and 868.5 MHz.
Channel | Frequency (MHz) | Bandwidth (kHz) | Sp Factor / Data Rate |
---|---|---|---|
0 | 864.8625 | 125 | 12-7 / 0-5 |
1 | 865.0625 | 125 | 12-7 / 0-5 |
2 | 865.4025 | 125 | 12-7 / 0-5 |
3 | 865.6025 | 125 | 12-7 / 0-5 |
4 | 865.9850 | 125 | 12-7 / 0-5 |
5 | 866.2000 | 125 | 12-7 / 0-5 |
6 | 866.4000 | 125 | 12-7 / 0-5 |
7 | 866.6000 | 125 | 12-7 / 0-5 |
LoRa | 865.0625 | 250 | 7 / 6 |
FSK | 865.0625 | 125 | 50 kbps |
- RX2 window: 866.5500 MHz, DR2 (SF10)
- Max power: 36 dBm
- Coding rate: 4/5
- Duty cycle: off (no duty cycle)
Also see Sending Data, Why We Operate At India’s Frequencies